Frequently Asked Questions
Answers to common questions about flooring material selection, installation methods, technical performance, and routine maintenance.
All Questions
What are the common types of epoxy flooring?
Common epoxy flooring systems include epoxy thin coatings, epoxy self-leveling floors, epoxy mortar floors, epoxy decorative quartz floors, and epoxy terrazzo. These systems differ in their material structures, decorative finishes, application thicknesses, and performance.
The appropriate system should be selected according to the project environment, load requirements, desired surface finish, and budget.
Enquire about epoxy flooring →What is the difference between an epoxy thin coating and an epoxy self-leveling floor?
An epoxy thin coating uses a relatively thin coating structure and is suitable for basic floor protection and surface decoration. An epoxy self-leveling system uses materials with flow and leveling properties to create a smoother, more continuous surface.
The two systems differ in material consumption, substrate requirements, installation methods, and final appearance. Selection should be based on the project requirements.
What is the difference between epoxy decorative quartz flooring and epoxy terrazzo?
Epoxy decorative quartz flooring creates a decorative finish using quartz aggregates in different colors, producing a distinctive granular texture. Epoxy terrazzo combines resin with decorative aggregates of different sizes. The material is placed, cured, and ground to create an integrated decorative surface.
The two systems differ in aggregate composition, installation methods, surface appearance, and cost.
Request a decorative flooring solution →Where is epoxy flooring suitable for use?
Epoxy flooring is widely used in industrial plants, electronics workshops, warehouses and logistics facilities, underground parking areas, commercial spaces, and some clean production areas.
The requirements of each location should be considered, including abrasion resistance, chemical resistance, slip resistance, static control, and ease of cleaning and maintenance.
Does the substrate need to be prepared before epoxy terrazzo installation?
Yes. Before installation, the concrete substrate should be checked for strength, flatness, moisture condition, and cracks.
Depending on the actual substrate condition, preparation may include grinding, cleaning, repairs, and the application of a suitable primer. Structural cracks and expansion joints require separate assessment and treatment; they should not simply be covered with the finishing material.
What polyurethane flooring product ranges does TUTR offer?
TUTR offers polyurethane flooring materials for different applications, including polyurethane floor coatings, self-leveling systems, and polyurethane mortar systems.
Product ranges differ in elasticity, surface finish, abrasion resistance, and suitable operating environments. The appropriate product should be selected with reference to the technical documentation for the specific model.
What is the difference between polyurethane flooring and epoxy flooring?
Epoxy flooring generally offers high surface hardness and good adhesion. Polyurethane flooring can be formulated to provide different levels of elasticity and weather resistance.
The two materials have different suitable environments and system structures. Selection should take into account service intensity, temperature changes, chemical exposure, and budget.
What does a polyurethane self-leveling floor look like?
A polyurethane self-leveling floor generally forms a continuous, level surface without obvious joints. Depending on the product formulation and installation method, the finish can have different gloss levels and surface textures.
If a smooth finish is required, the desired appearance should be specified during product selection and confirmed using an actual product sample and the relevant technical documentation.
Which industrial environments are suitable for polyurethane mortar flooring?
Polyurethane mortar can be used in industrial areas where abrasion resistance, impact resistance, ease of cleaning, and environmental adaptability are important.
Common application areas include food processing facilities, production workshops, and some heavy-duty industrial environments. Suitability should be assessed according to the material model, temperature conditions, and chemical exposure.
Can polyurethane mortar create the same decorative finish as epoxy quartz flooring?
They are different material systems. Polyurethane mortar is primarily used for functional industrial flooring and should not be considered equivalent to the decorative finish of epoxy quartz flooring.
If a decorative finish with colored quartz aggregates is required, the appropriate epoxy decorative quartz system is recommended.
Enquire about decorative quartz flooring →What forms of anti-static PVC flooring are available?
Anti-static PVC flooring is mainly available in tiles and rolls. Tiles are generally installed as individual square or rectangular pieces, while rolls are suitable for areas that require a more continuous floor covering.
The two formats differ in joint treatment, installation methods, and suitability for site conditions.
What are the common specifications of anti-static PVC flooring?
TUTR's commonly used anti-static PVC tile specification is 600 × 600 mm, with a thickness of 2 mm.
The roll specification is 2 m × 20 m, with a thickness of 2 mm. Actual supply specifications are subject to confirmation for the specific product model and order.
What is the difference between conductive and dissipative PVC flooring?
Conductive and dissipative refer to two different categories of electrostatic-control performance.
They differ in electrical resistance characteristics and the way static charges are discharged. Selection should be based on the project's required resistance range, test method, and grounding design. The product name alone is not enough to determine suitability.
Is copper foil required when installing anti-static PVC flooring?
The need for copper foil depends on the selected product type and the design of the electrostatic grounding system. Conductive systems generally require the appropriate conductive connections and grounding network.
Copper foil layout, connection methods, and the number of grounding points should be determined according to the project requirements.
What is the installation process for anti-static PVC flooring?
A typical installation process includes substrate grinding and cleaning, adhesive application, installation of copper foil and the grounding network where required, PVC flooring installation, seam welding, and subsequent surface treatment.
Installation details may vary between products and should follow the requirements of the specific material and system.
Which installation accessories are needed for anti-static PVC flooring?
Common accessories include PVC flooring adhesive, conductive adhesive, copper foil, welding rods, and floor maintenance materials.
The required accessories should be selected according to the PVC flooring type, grounding requirements, and installation method. Some standard accessories may also be sourced locally, depending on project conditions.
Which anti-static flooring systems can TUTR provide?
TUTR's anti-static flooring product range includes PVC tiles, PVC rolls, anti-static epoxy flooring materials, and anti-static raised access floors.
These systems have different structures and installation methods. Selection should be based on the project environment and electrostatic-control requirements.
What is anti-static raised access flooring?
Anti-static raised access flooring is an elevated floor structure. Floor panels are supported above the original floor by a support system, creating an accessible space underneath for cables and equipment.
Common applications include data centers, electronic equipment rooms, and some precision manufacturing areas.
What is the difference between anti-static PVC flooring and anti-static raised access flooring?
Anti-static PVC flooring is generally installed directly over a prepared substrate to create a continuous floor covering.
Raised access flooring uses a support structure to create an elevated space, making it more suitable for environments where cables need to be routed and maintained beneath the floor. The two systems have different applications and construction structures.
How do I choose the right anti-static flooring system?
Consider the required resistance range, grounding method, equipment layout, floor load requirements, cleaning requirements, and future maintenance conditions.
If underfloor cable routing is required, raised access flooring should be evaluated. If a direct floor covering is needed, anti-static PVC or an epoxy system may be considered.
Enquire about anti-static system selection →What are the concrete substrate requirements before flooring installation?
The substrate should have sufficient strength and flatness. It should be dry and clean, without obvious oil contamination, loose layers, laitance, or other contaminants that may affect adhesion.
Specific substrate requirements should be confirmed against the technical documentation of the selected flooring system.
How can I determine whether a concrete substrate is suitable for flooring installation?
Check the substrate strength, flatness, surface condition, moisture condition, and whether cracks or hollow areas are present.
Moisture content should be verified using a test method accepted for the project. The results must meet the requirements of the selected flooring material before installation.
How should cracks and expansion joints in concrete floors be treated?
First determine whether a crack is a surface crack or a structural crack, and check whether the expansion joint is still subject to movement.
Depending on the actual condition, the appropriate treatment may include crack repair, joint filling, or retaining the movement joint. Structural cracks should not be covered without proper assessment.
Why is the substrate usually ground before flooring installation?
Grinding can remove laitance, loose concrete, some old coatings, and contaminants from the concrete surface while improving the substrate condition.
The required level of grinding depends on the material type, substrate condition, and installation plan.
Is a primer required before installing epoxy and polyurethane flooring?
Many resin flooring systems require a compatible primer to improve substrate sealing, penetration, and interlayer adhesion.
The specific primer type, consumption, and application method depend on the material system and should follow the technical documentation for the relevant product.
How long after flooring installation can the floor be put into service?
Curing times vary between materials. Light foot traffic, equipment movement, and heavy-duty use also require different opening times.
The actual opening time should be determined from the product TDS, taking into account ambient temperature, humidity, and application thickness.
What causes bubbles to appear on an epoxy floor after installation?
Common causes include a damp substrate, air released from pores in the substrate, insufficient primer treatment, improper material mixing, and changes in site conditions.
Check where the bubbles occur and inspect the substrate before deciding whether grinding, repair, or recoating is required.
What causes delamination or poor adhesion in flooring?
Possible causes include insufficient substrate strength, surface contamination, excessive moisture, an incompatible primer, or incorrect timing between coating layers.
Inspect the affected area and the failure interface to identify the actual issue between the substrate and coating before carrying out repairs.
What causes color differences on a flooring surface?
Possible causes include different material batches, mixing ratios, mixing consistency, application thickness, substrate absorption, and site lighting.
It is recommended to use consistent material batches and installation methods, and to approve a sample area before large-scale installation.
What are the common causes of cracks in flooring?
Possible causes include cracking in the concrete substrate, structural movement, improper treatment of expansion joints, insufficient substrate strength, or installation issues.
First determine whether the crack is still developing. The appropriate repair material and follow-up installation method can then be selected.
How should industrial flooring be cleaned and maintained?
Select suitable cleaning equipment and cleaning agents according to the flooring material. Remove dust, oil, and production residues regularly.
For resin flooring, avoid unapproved highly corrosive cleaning agents. PVC flooring should be cleaned and maintained according to the requirements of the relevant product.
What industrial flooring materials can TUTR provide?
TUTR's product range includes PVC flooring, epoxy flooring materials, polyurethane flooring materials, and anti-static flooring systems.
Specific product models, material structures, and installation solutions can be determined according to project requirements.
View product technical documents →How do I choose the right flooring material for an industrial project?
Selection should take into account the project industry, operating environment, substrate condition, vehicle and equipment loads, abrasion resistance requirements, chemical exposure, anti-static requirements, and desired decorative finish.
The system should not be selected on material price alone. Installation, maintenance, and actual operating requirements should also be considered.
Can TUTR provide TDS, SDS, and test reports?
Available technical documents can be provided according to the specific product model, including TDS, SDS, and relevant test reports.
Documentation and test items vary between products. The applicable scope of each document is subject to the product model and the contents of the report.
Visit the Resource Center →Can product samples be requested before placing an order?
Sample arrangements can be discussed according to the product type, sample specifications, and project requirements. For PVC flooring, the color, pattern, and product format can be confirmed when arranging samples.
Samples of resin-based materials need to be arranged according to the specific product and shipping conditions.
What project information is needed to obtain a flooring material quotation?
Please provide the project country and city, installation area, required flooring type, substrate condition, operating environment, performance requirements, and expected delivery date.
If installation services are required, please also clarify whether TUTR is expected to provide the installation, work with a local installation team, or provide technical guidance.
Submit your project requirements →How are product MOQ, production lead time, shipping, and payment terms determined?
Minimum order quantities, packaging specifications, and production lead times vary by product. They need to be confirmed according to the product model, order quantity, and destination.
Shipping method, delivery location, and payment terms will be specified in the formal quotation. Payment arrangements for resin-based materials are subject to the order terms confirmed by both parties.
Request a project quotation →No matching questions found
Try another keyword or select a different FAQ category.
Have another technical question?
Contact the TUTR technical team